SAMMY UI is optimized for resolutions with a width 1024px and higher.
Automated Response to Integrity Violations
SI-7(5): Automated Response to Integrity Violations
Automatically [Selection (one or more): shut the system down; restart the system; implement [Assignment: organization-defined controls]] when integrity violations are discovered.
Implementation
Description

Organizations may define different integrity-checking responses by type of information, specific information, or a combination of both. Types of information include firmware, software, and user data. Specific information includes boot firmware for certain types of machines. The automatic implementation of controls within organizational systems includes reversing the changes, halting the system, or triggering audit alerts when unauthorized modifications to critical security files occur.